COMBINED AC-DC HARNESS INSTALLATION INSTRUCTIONS FOR
PLASTIC LINER CUSTOMCOOL MODELS WITH UNI-DAMPER
*** Steps 1-7 and 13-21, 23-25 apply to all, Steps 8-12,
22 are model-specific.
1. Unplug the Refrigerator and disconnect the main
water line.
2. Unscrew 3 screws in the FF side and 1 screw in the
FZ side to loosen the CustomCool assembly.
FF Side (3 Screws)
FZ Side (1 Screw)
3. Unscrew 7 screws then disassemble access cover.
4. Unscrew 8 screws then disassemble the main board
cover.
5. Unscrew the ground connection on the case back
and unplug the 3 pin male connector in the Hi Side
area.
6. Unplug the CustomCool fan 2 pin connector and
damper board connection on the main board. The
correct connectors are identified coming out of the
Sleeve as Shown.
Damper
Board
Connection
CustomCool
Fan Connection